The table below describe a protocol for the decontamination of cryostored carriers prior to warming. The protocol involve washing the frozen carrier retrieved from cryo-storage, with sterile Liquid Nitrogen, prior to warming.

Decontamination of carriers using sterile Liquid Nitrogen ("3-Wash")

This protocol is recommended for any warming procedure, both if the carrier was prepared and stored with sterile LN2 or if it was vitrified/prepared/stored in non-sterile LN2.

DOWNLOAD PROTOCOL

UTILITY
The new NTERILIZER N-Bath is part of an easy-to-implement system to sterilize liquid nitrogen based on specifically designed sterile disposable sleeves for vitrification and warming.

The disposable is equipped with a special UV sensitive label, and the process is traced by a double labelling. The sterilization data is backupped in a web portal based on blockchain technology. The device is given for loan to Nterilizer contract subscribers and the disposable sleeves are sold at cost of a cryo-carrier. The contract encloses website access and microbiological test for installation. The purchase of a minimum number of 600 sleeves per year is required.